ground-fault current

См. также в других словарях:

  • Fault current limiter — A Fault Current Limiter (FCL) is a device which limits the prospective fault current when a fault occurs (eg in a power transmission network). The term is generally applied to superconducting devices, whereas non superconducting devices (such as… …   Wikipedia

  • Fault current — A fault current is an abnormal current in an electric circuit due to a fault (usually a short circuit or abnormally low impedance path).In terms of installation wiring, the prospective short circuit current must be known as it influences the… …   Wikipedia

  • Fault indicator — A fault indicator is a device which provides visual indication of an electrical fault. They are used in electric power distribution networks as a means of automatically detecting and identifying faults. Basic principles During an electrical fault …   Wikipedia

  • Ground-Based Midcourse Defense — (GMD) is a component of the national missile defense strategy of the United States administered by the U.S. Missile Defense Agency. Previously known as National Missile Defense (NMD), the name was changed in 2002 to differentiate it from other… …   Wikipedia

  • Ground (electricity) — In electrical engineering, ground or earth may be the reference point in an electrical circuit from which other voltages are measured, or a common return path for electric current, or a direct physical connection to the Earth. A typical earthing… …   Wikipedia

  • Ground and neutral — For uses of the term ground or earth in electricity but not in the context of mains wiring, see ground (electricity). Since the neutral point of an electrical supply system is often connected to earth ground, ground and neutral are closely… …   Wikipedia

  • Current sea level rise — This article is about the current and future rise in sea level associated with global warming. For sea level changes in Earth s history, see Sea level#Changes through geologic time. Sea level measurements from 23 long tide gauge records in… …   Wikipedia

  • Fault (power engineering) — A fault is any abnormal situation in an electrical system in which the electrical current may or may not flow through the intended part/s.Fault is a condition when the current or voltage in any circuit do not flow in the same phase. in other… …   Wikipedia

  • Residual-current device — A two pole residual current device A Residual Current Device is a generic term covering both RCCBs and RCBOs. A Residual Current Circuit Breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the… …   Wikipedia

  • High Voltage Isolation and Ground Potential Rise — This article outlines the principles of High Voltage Isolation (HVI) and Ground Potential Rise (GPR). Most often questions of concern arise to anyone associated with the use of any communication signal (analog or digital) via a metallic or fiber… …   Wikipedia

  • Arc-fault circuit interrupter — An arc fault circuit interrupter (AFCI) is a circuit breaker designed to prevent fires by detecting non working electrical arcs and disconnect power before the arc starts a fire. The AFCI should distinguish between a working arc that may occur in …   Wikipedia